Omega CDTX-90 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Sensores Omega CDTX-90. Omega CDTX-90 User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
CDTX-90 Series
Conductivity/Resistivity Transmitters
Conductivity/Resistivity
62.50 uS/cm
25.0° C
ENTER
www.omega.com
Shop online at
ISO 9002
CERTIFIED
CORPORATE QUALITY
MANCHESTER, UK
ISO 9001
CERTIFIED
CORPORATE QUALITY
STAMFORD, CT
Users Guide
Vista de página 0
1 2 3 4 5 6 ... 19 20

Resumo do Conteúdo

Página 1 - User’s Guide

CDTX-90 SeriesConductivity/Resistivity TransmittersConductivity/Resistivity 62.50 uS/cm25.0° CENTER www.omega.com e-mail: [email protected] online

Página 2

page 8Select CUSTOM only if you are connecting a certifi ed conductivity sensor. Select STANDARD for all other systems. For STANDARD sensors: Se

Página 3 - (2.5 in.)

page 9 Contrast: 3 > Cond Decimal: ****.* > Averaging O >Loop Adjust: 4.00 mA >Loop Adjust: 20.00 mA > Temp Display: ºC >Temper

Página 4 - ≤ 100 ft. (30 m)

page 10 Cell Constant: Standard > Cell: Standard 1 >Cell: Custom 1.0000 >Cond Units: μS >PPM Factor: 2.00 > Set: Temperature >

Página 5 - Output +

page 11Adjust the LCD contrast for best viewing. A setting of 1 is lower contrast, 5 is higher. In general, select lower contrast if the display is

Página 6 - PLC or Recorder

page 12Select CUSTOM only if you are connecting a certifi ed conductivity sensor. Select STANDARD for all other systems. For STANDARD sensors: S

Página 7

page 13 Contrast: 3 > Cond Decimal: ****.* > Averaging O >Loop1 Adjust: 4.00 mA >Loop1 Adjust: 20.00 mA > Temp Display: ºC >Tem

Página 8 - VIEW menu

page 14Calibration Procedure1. RequirementsThe CDTX-90 Transmitter is factory calibrated using simulated input signals. System calibration will reduc

Página 9 - CALIBRATE

page 15Display Condition Suggested SolutionsPossible Causes"- - - -" Value Must be lessthan 3Value must be greater than 0"Value must b

Página 11

WARRANTY/DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date o

Página 12 - CDTX-90-2 Calibrate Menu

It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certi cation of its pr

Página 13 - CDTX-90-2 Options Menu

6-8850.090-OM/(D 10/08) M3632/1008Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course!Shop online at www.omega.comT

Página 14 - CDTX-90-3 Calibrate Menu

page 1CAUTION!• Remove power to unit before wiring input and output connections.• Follow instructions carefully to avoid personal injury.Omega C

Página 15

page 2Caution: Failure to fully open terminal jaws before removing wire may permanently damage instrument.Wiring Procedure 1. Remove 0.5 - 0.625 in

Página 16 - Calibration Procedure

page 3CDTX-90-1 System Power/Loop Connections Stand-alone application, no current loop usedTransmitter4321Sys. Pwr.Loop -Sys. Pwr.Loop +AUXPower -AUXP

Página 17 - Troubleshooting

page 4Stand-alone application, no current loop usedTransmitter Terminals4321Sys. Pwr.Loop -Sys. Pwr.Loop +AUXPower -AUXPower +Power SupplyDC 1

Página 18

page 5Sensr Gnd(SHIELD)Iso. Gnd(BLACK)Temp. IN(WHITE)Signal IN(RED)14131211Output 2-Output 2+Output 1-Output 1+10987Loop 2-Loop 2+System PwrLoop -Syst

Página 19 - RETURN REQUESTS/INQUIRIES

page 6VIEW menu• During normal operation, the transmitter displays the VIEW menu.• When editing the CALIBRATE or OPTIONS menus, the transmitter will

Página 20 - Shop online at www.omega.com

page 7Notes on Steps 5 and 6:• All output functions remain active during editing.• Only the fl ashing element can be edited.• RIGHT ARROW key advanc